acquisition_library#

Standard acquisition protocols for use with the quantify_scheduler.

Module Contents#

Classes#

Acquisition

An operation representing data acquisition at the quantum-device abstraction layer.

AcquisitionOperation

Deprecated alias.

Trace

The Trace acquisition protocol measures a signal s(t).

WeightedIntegratedSeparated

Weighted integration acquisition protocol where two sets weights

SSBIntegrationComplex

Single sideband integration acquisition protocol with complex results.

ThresholdedAcquisition

Acquisition protocol allowing to control rotation and threshold.

NumericalSeparatedWeightedIntegration

Subclass of WeightedIntegratedSeparated with parameterized waveforms as weights.

NumericalWeightedIntegrationComplex

Deprecated, renamed to NumericalSeparatedWeightedIntegration.

NumericalWeightedIntegration

Subclass of NumericalSeparatedWeightedIntegration returning a complex number.

TriggerCount

Trigger counting acquisition protocol returning an integer.

TimetagTrace

The TimetagTrace acquisition protocol records timetags within an acquisition window.

Timetag

Acquire a single timetag per acquisition index.

class Acquisition(name: str)[source]#

Bases: quantify_scheduler.Operation

An operation representing data acquisition at the quantum-device abstraction layer.

An Acquisition must consist of (at least) an AcquisitionProtocol specifying how the acquired signal is to be processed, and an AcquisitionChannel and AcquisitionIndex specifying where the acquired data is to be stored in the RawDataset.

N.B. This class helps differentiate an acquisition operation from the regular operations. This enables us to use plot_acquisition_operations() to highlight acquisition pulses in the pulse diagrams.

class AcquisitionOperation(name: str)[source]#

Bases: Acquisition

Deprecated alias.

class Trace(duration: float, port: str, clock: str, acq_channel: int = 0, acq_index: int = 0, bin_mode: quantify_scheduler.enums.BinMode | str = BinMode.AVERAGE, t0: float = 0)[source]#

Bases: Acquisition

The Trace acquisition protocol measures a signal s(t).

Only processing performed is rescaling and adding units based on a calibrated scale. Values are returned as a raw trace (numpy array of float datatype). Length of this array depends on the sampling rate of the acquisition device.

Important

The exact duration of this operation, and the possible bin modes may depend on the control hardware. Please consult your hardware vendor’s Reference guide for more information.

Parameters:
  • port – The acquisition port.

  • clock – The clock used to demodulate the acquisition.

  • duration – The acquisition duration in seconds.

  • acq_channel – The data channel in which the acquisition is stored, is by default 0. Describes the “where” information of the measurement, which typically corresponds to a qubit idx.

  • acq_index – The data register in which the acquisition is stored, by default 0. Describes the “when” information of the measurement, used to label or tag individual measurements in a large circuit. Typically corresponds to the setpoints of a schedule (e.g., tau in a T1 experiment).

  • bin_mode – Describes what is done when data is written to a memory location that already contains values. Which bin mode can be used for Trace acquisitions may depend on the hardware. BinMode.AVERAGE, the default, works on most hardware. This bin mode stores the weighted average value of the new result and the old values. BinMode.FIRST is used for hardware where only the result of the first acquisition in a Schedule is stored, e.g. for a Trace acquisition with Qblox QTM modules.

  • t0 – The acquisition start time in seconds, by default 0.

class WeightedIntegratedSeparated(waveform_a: Dict[str, Any], waveform_b: Dict[str, Any], port: str, clock: str, duration: float, acq_channel: int = 0, acq_index: int = 0, bin_mode: quantify_scheduler.enums.BinMode | str = BinMode.APPEND, phase: float = 0, t0: float = 0)[source]#

Bases: Acquisition

Weighted integration acquisition protocol where two sets weights are applied separately to the real and imaginary parts of the signal.

Weights are applied as:

\[\widetilde{A} = \int \mathrm{Re}(S(t))\cdot W_A(t) \mathrm{d}t\]
\[\widetilde{B} = \int \mathrm{Im}(S(t))\cdot W_B(t) \mathrm{d}t\]
Parameters:
  • waveform_a – The complex waveform used as integration weights \(W_A(t)\).

  • waveform_b – The complex waveform used as integration weights \(W_B(t)\).

  • port – The acquisition port.

  • clock – The clock used to demodulate the acquisition.

  • duration – The acquisition duration in seconds.

  • acq_channel – The data channel in which the acquisition is stored, by default 0. Describes the “where” information of the measurement, which typically corresponds to a qubit idx.

  • acq_index – The data register in which the acquisition is stored, by default 0. Describes the “when” information of the measurement, used to label or tag individual measurements in a large circuit. Typically corresponds to the setpoints of a schedule (e.g., tau in a T1 experiment).

  • bin_mode – Describes what is done when data is written to a register that already contains a value. Options are “append” which appends the result to the list or “average” which stores the weighted average value of the new result and the old register value, by default BinMode.APPEND.

  • phase – The phase of the pulse and acquisition in degrees, by default 0.

  • t0 – The acquisition start time in seconds, by default 0.

Raises:

NotImplementedError

class SSBIntegrationComplex(port: str, clock: str, duration: float, acq_channel: int = 0, acq_index: int = 0, bin_mode: quantify_scheduler.enums.BinMode | str = BinMode.AVERAGE, phase: float = 0, t0: float = 0)[source]#

Bases: Acquisition

Single sideband integration acquisition protocol with complex results.

A weighted integrated acquisition on a complex signal using a square window for the acquisition weights.

The signal is demodulated using the specified clock, and the square window then effectively specifies an integration window.

Parameters:
  • port – The acquisition port.

  • clock – The clock used to demodulate the acquisition.

  • duration – The acquisition duration in seconds.

  • acq_channel – The data channel in which the acquisition is stored, by default 0. Describes the “where” information of the measurement, which typically corresponds to a qubit idx.

  • acq_index – The data register in which the acquisition is stored, by default 0. Describes the “when” information of the measurement, used to label or tag individual measurements in a large circuit. Typically corresponds to the setpoints of a schedule (e.g., tau in a T1 experiment).

  • bin_mode – Describes what is done when data is written to a register that already contains a value. Options are “append” which appends the result to the list or “average” which stores the weighted average value of the new result and the old register value, by default BinMode.AVERAGE.

  • phase – The phase of the pulse and acquisition in degrees, by default 0.

  • t0 – The acquisition start time in seconds, by default 0.

waveform_i[source]#
waveform_q[source]#
class ThresholdedAcquisition(port: str, clock: str, duration: float, acq_channel: int = 0, acq_index: int = 0, bin_mode: quantify_scheduler.enums.BinMode | str = BinMode.AVERAGE, feedback_trigger_label: str | None = None, phase: float = 0, t0: float = 0, acq_rotation: float = 0, acq_threshold: float = 0)[source]#

Bases: Acquisition

Acquisition protocol allowing to control rotation and threshold.

This acquisition protocol is similar to the SSBIntegrationComplex acquisition protocol, but the complex result is now rotated and thresholded to produce a “0” or a “1”, as controlled by the parameters for rotation angle <qubit>.measure.acq_rotation and threshold value <qubit>.measure.acq_threshold in the device configuration (see example below).

The rotation angle and threshold value for each qubit can be set through the device configuration.

Note

Thresholded acquisition is currently only supported by the Qblox backend.

Examples

from quantify_scheduler import Schedule
from quantify_scheduler.device_under_test.transmon_element import BasicTransmonElement
from quantify_scheduler.operations.acquisition_library import ThresholdedAcquisition

# set up qubit
qubit = BasicTransmonElement("q0")
qubit.clock_freqs.readout(8.0e9)

# set rotation and threshold value
rotation, threshold = 20, -0.1
qubit.measure.acq_rotation(rotation)
qubit.measure.acq_threshold(threshold)

# basic schedule
schedule = Schedule("thresholded acquisition")
schedule.add(ThresholdedAcquisition(port="q0:res", clock="q0.ro", duration=1e-6))
{'name': '68c5e1e9-a078-453d-a64b-82d6ff059171', 'operation_id': '-295859077309358445', 'timing_constraints': [{'rel_time': 0, 'ref_schedulable': None, 'ref_pt_new': None, 'ref_pt': None}], 'label': '68c5e1e9-a078-453d-a64b-82d6ff059171'}
Parameters:
  • port (str) – The acquisition port.

  • clock (str) – The clock used to demodulate the acquisition.

  • duration (float) – The acquisition duration in seconds.

  • acq_channel (int) – The data channel in which the acquisition is stored, by default 0. Describes the “where” information of the measurement, which typically corresponds to a qubit idx.

  • acq_index (int) – The data register in which the acquisition is stored, by default 0. Describes the “when” information of the measurement, used to label or tag individual measurements in a large circuit. Typically corresponds to the setpoints of a schedule (e.g., tau in a T1 experiment).

  • bin_mode (BinMode or str) – Describes what is done when data is written to a register that already contains a value. Options are “append” which appends the result to the list or “average” which stores the weighted average value of the new result and the old register value, by default BinMode.AVERAGE.

  • feedback_trigger_label (str) – The label corresponding to the feedback trigger, which is mapped by the compiler to a feedback trigger address on hardware, by default None.

  • phase (float) – The phase of the pulse and acquisition in degrees, by default 0.

  • t0 (float) – The acquisition start time in seconds, by default 0.

waveform_i[source]#
waveform_q[source]#
class NumericalSeparatedWeightedIntegration(port: str, clock: str, weights_a: List[complex] | numpy.ndarray, weights_b: List[complex] | numpy.ndarray, weights_sampling_rate: float = 1000000000.0, interpolation: str = 'linear', acq_channel: int = 0, acq_index: int = 0, bin_mode: quantify_scheduler.enums.BinMode | str = BinMode.APPEND, phase: float = 0, t0: float = 0)[source]#

Bases: WeightedIntegratedSeparated

Subclass of WeightedIntegratedSeparated with parameterized waveforms as weights.

A WeightedIntegratedSeparated class using parameterized waveforms and interpolation as the integration weights.

Weights are applied as:

\[\widetilde{A} = \int \mathrm{Re}(S(t)\cdot W_A(t) \mathrm{d}t\]
\[\widetilde{B} = \int \mathrm{Im}(S(t))\cdot W_B(t) \mathrm{d}t\]
Parameters:
  • port – The acquisition port.

  • clock – The clock used to demodulate the acquisition.

  • weights_a – The list of complex values used as weights \(A(t)\) on the incoming complex signal.

  • weights_b – The list of complex values used as weights \(B(t)\) on the incoming complex signal.

  • weights_sampling_rate – The rate with which the weights have been sampled, in Hz. By default equal to 1 GHz. Note that during hardware compilation, the weights will be resampled with the sampling rate supported by the target hardware.

  • interpolation – The type of interpolation to use, by default “linear”. This argument is passed to interp1d.

  • acq_channel – The data channel in which the acquisition is stored, by default 0. Describes the “where” information of the measurement, which typically corresponds to a qubit idx.

  • acq_index – The data register in which the acquisition is stored, by default 0. Describes the “when” information of the measurement, used to label or tag individual measurements in a large circuit. Typically corresponds to the setpoints of a schedule (e.g., tau in a T1 experiment).

  • bin_mode – Describes what is done when data is written to a register that already contains a value. Options are “append” which appends the result to the list or “average” which stores the weighted average value of the new result and the old register value, by default BinMode.APPEND.

  • phase – The phase of the pulse and acquisition in degrees, by default 0.

  • t0 – The acquisition start time in seconds, by default 0.

t_samples[source]#
weights_a[source]#
weights_b[source]#
waveforms_a[source]#
waveforms_b[source]#
class NumericalWeightedIntegrationComplex(waveform_a: Dict[str, Any], waveform_b: Dict[str, Any], port: str, clock: str, duration: float, acq_channel: int = 0, acq_index: int = 0, bin_mode: quantify_scheduler.enums.BinMode | str = BinMode.APPEND, phase: float = 0, t0: float = 0)[source]#

Bases: WeightedIntegratedSeparated

Deprecated, renamed to NumericalSeparatedWeightedIntegration.

class NumericalWeightedIntegration(port: str, clock: str, weights_a: List[complex] | numpy.ndarray, weights_b: List[complex] | numpy.ndarray, weights_sampling_rate: float = 1000000000.0, interpolation: str = 'linear', acq_channel: int = 0, acq_index: int = 0, bin_mode: quantify_scheduler.enums.BinMode | str = BinMode.APPEND, phase: float = 0, t0: float = 0)[source]#

Bases: NumericalSeparatedWeightedIntegration

Subclass of NumericalSeparatedWeightedIntegration returning a complex number.

Parameters:
  • port – The acquisition port.

  • clock – The clock used to demodulate the acquisition.

  • weights_a – The list of complex values used as weights \(A(t)\) on the incoming complex signal.

  • weights_b – The list of complex values used as weights \(B(t)\) on the incoming complex signal.

  • weights_sampling_rate – The rate with which the weights have been sampled, in Hz. By default equal to 1 GHz. Note that during hardware compilation, the weights will be resampled with the sampling rate supported by the target hardware.

  • t – The time values of each weight. This parameter is deprecated in favor of weights_sampling_rate. If a value is provided for t, the weights_sampling_rate parameter will be ignored.

  • interpolation – The type of interpolation to use, by default “linear”. This argument is passed to interp1d.

  • acq_channel – The data channel in which the acquisition is stored, by default 0. Describes the “where” information of the measurement, which typically corresponds to a qubit idx.

  • acq_index – The data register in which the acquisition is stored, by default 0. Describes the “when” information of the measurement, used to label or tag individual measurements in a large circuit. Typically corresponds to the setpoints of a schedule (e.g., tau in a T1 experiment).

  • bin_mode – Describes what is done when data is written to a register that already contains a value. Options are “append” which appends the result to the list or “average” which stores the weighted average value of the new result and the old register value, by default BinMode.APPEND.

  • phase – The phase of the pulse and acquisition in degrees, by default 0.

  • t0 – The acquisition start time in seconds, by default 0.

class TriggerCount(port: str, clock: str, duration: float, acq_channel: int = 0, acq_index: int = 0, bin_mode: quantify_scheduler.enums.BinMode | str = BinMode.APPEND, t0: float = 0)[source]#

Bases: Acquisition

Trigger counting acquisition protocol returning an integer.

The trigger acquisition mode is used to measure how many times the trigger level is surpassed. The level is set in the hardware configuration.

Important

The exact duration of this operation, and the possible bin modes may depend on the control hardware. Please consult your hardware vendor’s Reference guide for more information.

Parameters:
  • port – The acquisition port.

  • clock – The clock used to demodulate the acquisition.

  • duration – The duration of the operation in seconds.

  • acq_channel – The data channel in which the acquisition is stored, by default 0. Describes the “where” information of the measurement, which typically corresponds to a qubit idx.

  • acq_index – The data register in which the acquisition is stored, by default 0. Describes the “when” information of the measurement, used to label or tag individual measurements in a large circuit. Typically corresponds to the setpoints of a schedule (e.g., tau in a T1 experiment).

  • bin_mode – Describes what is done when data is written to a register that already contains a value. Options are “append” which appends the result to the list or “average” which stores the count value of the new result and the old register value, by default BinMode.APPEND.

  • t0 – The acquisition start time in seconds, by default 0.

class TimetagTrace(duration: float, port: str, clock: str = DigitalClockResource.IDENTITY, acq_channel: int = 0, acq_index: int = 0, bin_mode: quantify_scheduler.enums.BinMode | str = BinMode.APPEND, time_ref: quantify_scheduler.enums.TimeRef | str = TimeRef.START, t0: float = 0)[source]#

Bases: Acquisition

The TimetagTrace acquisition protocol records timetags within an acquisition window.

Important

The exact duration of this operation, and the possible bin modes may depend on the control hardware. Please consult your hardware vendor’s Reference guide for more information.

Parameters:
  • port – The acquisition port.

  • clock – The clock used to demodulate the acquisition.

  • duration – The acquisition duration in seconds.

  • acq_channel – The data channel in which the acquisition is stored, is by default 0. Describes the “where” information of the measurement, which typically corresponds to a qubit idx.

  • acq_index – The data register in which the acquisition is stored, by default 0. Describes the “when” information of the measurement, used to label or tag individual measurements in a large circuit. Typically corresponds to the setpoints of a schedule (e.g., tau in a T1 experiment).

  • bin_mode – Describes what is done when data is written to a register that already contains a value. Only “BinMode.APPEND” is available at the moment; this option concatenates timetag results with the same acquisition channel and index.

  • time_ref

    Selects the time reference that the timetag is recorded in relation to. String enumeration, one of:

    • start (default): record relative to the start of the window.

    • end: record relative to the end of the window. Note that this always yields a negative timetag.

    • first: syntactic sugar for first#, where # is the current channel.

    • timestamp: record relative to the timestamp marked using the Timestamp operation.

  • t0 – The acquisition start time in seconds, by default 0.

class Timetag(duration: float, port: str, clock: str = DigitalClockResource.IDENTITY, acq_channel: int = 0, acq_index: int = 0, bin_mode: quantify_scheduler.enums.BinMode | str = BinMode.APPEND, time_source: quantify_scheduler.enums.TimeSource | str = TimeSource.FIRST, time_ref: quantify_scheduler.enums.TimeRef | str = TimeRef.START, t0: float = 0)[source]#

Bases: Acquisition

Acquire a single timetag per acquisition index.

Important

The exact duration of this operation, and the possible bin modes may depend on the control hardware. Please consult your hardware vendor’s Reference guide for more information.

Parameters:
  • port – The acquisition port.

  • clock – The clock used to demodulate the acquisition.

  • duration – The acquisition duration in seconds.

  • acq_channel – The data channel in which the acquisition is stored, by default 0. Describes the “where” information of the measurement, which typically corresponds to a qubit idx.

  • acq_index – The data register in which the acquisition is stored, by default 0. Describes the “when” information of the measurement, used to label or tag individual measurements in a large circuit. Typically corresponds to the setpoints of a schedule (e.g., tau in a T1 experiment).

  • bin_mode – Describes what is done when data is written to a register that already contains a value. Options are “append” which appends the result to the list or “average” which stores the weighted average value of the new result and the old register value, by default BinMode.APPEND.

  • time_source

    Selects the timetag data source for this acquisition type. String enumeration, one of:

    • first (default): record the first timetag in the window.

    • second: record the second timetag in the window. Can be used to measure pulse distance when combined with first as reference.

    • last: record the last timetag in the window.

  • time_ref

    Selects the time reference that the timetag is recorded in relation to. String enumeration, one of:

    • start (default): record relative to the start of the window.

    • end: record relative to the end of the window. Note that this always yields a negative timetag.

    • first: record relative to the first timetag in the window.

    • timestamp: record relative to the timestamp marked using the Timestamp operation.

  • t0 – The acquisition start time in seconds, by default 0.